Zones & Thresholds General Endurance · · 7 min read

The Modified Astrand Test: What the 2026 Equations Can (and Can't) Tell You About VO2peak and Lactate Threshold

A 2026 paper built VO2peak and lactate threshold equations from a modified Astrand treadmill test, but 28 young adults ran it to exhaustion. It is not a no-effort test.

AO
AthleteOS Data Science
TL;DR — The Answer

The 2026 Iuliano paper used a maximal, run-to-exhaustion treadmill test in 28 young, active adults to build equations for VO2peak and lactate threshold. It did not validate an easy, submaximal protocol. If you want to skip the all-out effort, the older submaximal options carry real error, roughly 7-9% for VO2 estimates and 7-12 beats per minute for max heart rate formulas.

If a headline told you a new treadmill test finds your VO2peak and lactate threshold without an all-out effort, check the fine print. The 2026 study behind that claim had 28 people run until they couldn’t continue.

That matters, because “easy test, lab-quality numbers” is exactly what most athletes hope to hear. This article separates what the paper did from what the internet says it did. Then it shows what you can realistically do instead.

What the 2026 modified Astrand test paper actually did

Iuliano and colleagues recruited 28 recreationally active young adults. Each ran a modified Åstrand incremental treadmill test to exhaustion. The team measured VO2peak (the highest oxygen use you reach in that test) with gas analysis. They also found lactate threshold using the OBLA method, the onset of blood lactate accumulation, conventionally set at 4 mmol/L.

From that data, they built new equations to estimate both numbers. The paper is in the British Medical Bulletin (2026).

In short: they ran everyone flat out, measured everything, then wrote formulas.

What’s missing is the fine print. The full text is paywalled, so the equations, their error margins and the exact stage speeds aren’t available here. Don’t trust any site that quotes them without the paper.

One thing is on the record. The authors say indirect estimates often don’t generalize or carry a high error margin. They also say lactate threshold is the hardest to estimate in the field because it needs blood samples.

The researchers themselves call for better field methods. This paper doesn’t claim to be the final one.

Maximal vs submaximal: why the test type matters

The original Åstrand-Rhyming test is a different animal. It’s a submaximal cycle test. You ride at one steady workload, and the tester records your heart rate in the final minutes. A nomogram (a chart) plus an age correction turns that heart rate into an estimated VO2max.

Heart rate needs about 4 to 6 minutes at constant load to settle. Measure earlier and the number reads too high.

The 2026 test is the opposite design. It steps up through stages until you’re done, and the equations assume that stage structure. So you can’t drop a heart rate from an easy run into them.

Think of it like estimating a car’s top speed. The original test listens to the engine at a steady cruise and guesses. The 2026 test floors it, records everything, then builds a rule for guessing next time.

Both ideas are useful. They aren’t interchangeable.

Reported Error in Predicted Max Heart Rate (bpm) 220 minus age 7-12 bpm Tanaka formula ~10 bpm Standard error of age-based formulas, from Robergs and Tanaka as cited in secondary sources. Lower is better. The top of each range is plotted.

How wrong are the usual shortcuts?

Age formulas set your zones every day, so their error matters. In 180 recreational marathoners, 220 minus age overestimated women’s measured max heart rate by 4.8 bpm. For men it underestimated by 2.8 bpm (Nikolaidis, 2018).

Translation: the formula can land you five beats off in either direction. Every zone built on it inherits that miss. Our guide on why 220 minus age is wrong shows how to find your real number.

The Uth ratio is a step better. It multiplies max heart rate divided by resting heart rate by 15.3 (men) or 14.5 (women). Its standard error was about 0.22 L/min, near 6.8%. But a recreational football group showed a factor of 14.6, so it isn’t universal.

A side-by-side look at the methods

MethodInputsTest typeReported errorValidated in
220 minus ageAgeNone7-12 bpmGeneral adults
Tanaka formulaAgeNone~10 bpmGeneral adults
Uth ratioMax and resting heart rateNeeds a max heart rate~6.8%Trained men, then mixed groups
Åstrand-Rhyming nomogramSteady-state heart rate, workload, ageSubmaximal, cycleCV 8.4-9.2%Up to age 65
Iuliano 2026 equationsModified treadmill stagesMaximal, treadmillNot available to us28 young active adults
Lab gas analysisGas exchangeMaximalReference methodAny

One secondary source also reports an error near 18% for the Åstrand test in adults aged 65 to 75, versus about 9% for a newer equation. Treat that as a pointer, not a fact. It comes from a table snippet that couldn’t be fully checked.

Reported Error in VO2max Estimates (%) Uth ratio ~6.8% Astrand-Rhyming (men) 8.4% Astrand-Rhyming (women) 9.2% Uth is a standard error. Astrand-Rhyming is a coefficient of variation from one validation sample, so the two aren't a perfect match. Lower is better.

Why a single heart rate can’t track your progress

Here’s a second trap. The Åstrand test uses one steady-state heart rate. That makes it poor at spotting change.

In a long follow-up covering 1949 to 1970, measured VO2max fell about 22% in women and 20% in men. The Åstrand test couldn’t detect that drop. A newer cycle test did better, with r = 0.75 between measured and estimated change (Bjorkman, 2021).

A bathroom scale that’s off by 8% is fine if it’s off the same way every day. This test isn’t that consistent.

Estimates tell you roughly where you stand. They’re weak at telling you whether you improved.

Lactate threshold without a meter

Lactate threshold is the hard one. A lab uses blood drops. Without that, you’re picking among imperfect proxies.

Options, from most to least effort:

Honest take: there’s no free lunch. Less effort means more error. Pick the method by how much error your plan can tolerate.

Heat, caffeine and other things that corrupt the number

Any heart rate based test inherits your day. Beta blockers blunt heart rate and invalidate it. Heat, dehydration, caffeine, bad sleep and altitude all push heart rate up at a given workload.

Test in similar conditions each time. Same time of day, same fuel, same surface. Treadmill and outdoor numbers don’t transfer cleanly, as track vs treadmill lactate testing explains.

The 2026 equations also came from young, recreationally active adults. That’s no guarantee for a 52-year-old triathlete, a cyclist, or a swimmer.

A quick example

Take a runner I’ll call Dana, 41, training for a half marathon. Her watch used 220 minus age, giving a max heart rate of 179. Her easy zone topped out at 70%, or 125 bpm.

After a hard hill finish and a short field test, her real max was 189. Seventy percent is now 132 bpm. Same athlete, seven beats of difference, and her “easy” runs were suddenly too slow to build much. (This is an illustrative example, not study data.)

Seven beats is the gap between a wrong zone and a useful one.

From any test result to training zones

The test matters less than what you do with it. Lab test, field test, or estimate: log it, set zones from it, then retest in 6 to 8 weeks. In AthleteOS you can enter any threshold or VO2 result and set your training zones from it. Update them when you retest, so a 220-minus-age guess doesn’t run your season. You can start with AthleteOS here.

Estimate, test, adjust. Repeat.

Frequently Asked Questions

Is the modified Astrand test a submaximal test?

The 2026 version is not. Participants ran a modified Astrand incremental treadmill test to exhaustion. The original Astrand-Rhyming cycle test is the submaximal one, using a single steady workload.

Can I estimate lactate threshold without a blood test?

Yes, but with more error. The 2026 paper's authors say lactate threshold is the hardest number to estimate in the field because it normally needs blood sampling. Treat any estimate as a starting point.

How accurate is the original Astrand-Rhyming test?

One validation sample reported a coefficient of variation of 8.4% in men and 9.2% in women. It was validated only up to age 65, and a steady-state heart rate can't track change over time well.

How accurate is 220 minus age for max heart rate?

Poorly for individuals. Reported error is roughly 7-12 beats per minute. In 180 recreational marathoners it overestimated women's max heart rate by 4.8 bpm on average.

Does the 2026 equation work for cyclists or swimmers?

Nobody knows. The sample was 28 young, recreationally active adults on a treadmill. Running-based equations shouldn't be applied to the bike or the pool.

#vo2peak#lactate-threshold#astrand-test#submaximal-testing